How should UPS lithium battery maintenance be regulated?

2022-10-14 14:00 The official
QR code
545

In the coming months, production of industrial lithium battery packs will decline, and prices may fluctuate slightly. However, due to the diversity of raw materials, although the price of industrial lithium batteries will fluctuate to a certain extent, the fluctuation of indoor space is not easy, which is closely related to the current development trend of this field. The current hot lithium-ion battery modules cost more than 90,000 yuan/ton. For some small retail investors, indoor space can be improved, but for some large customers, these aspects have no advantages. Today, storage power Xiaobian will take you to understand how to regulate the maintenance of UPS lithium batteries.

51.2V 105Ah高爾夫球車方形磷酸鐵鋰電池組.png

1. When using a lithium-ion UPS, pay attention to the main parameters of the UPS, such as input working voltage type, output waveform type, power, long power supply system time, conversion time, well-known lithium-ion brands, noise, equipment volume, and net weight. None of the UPS is suitable for full capacity. More than 20% of the output power capacity should be embedded, with the load running between 40% and 60% of the ups rated power.




2. Turn on the UPS power supply every time it is not used for a long time. You are advised to keep the standby UPS in the inverter state for at least two to three minutes every month to charge batteries and prolong the service life of the rechargeable batteries. When charging the battery, try to prevent overcharge and overvoltage of the battery. Moderate charge and discharge will help to charge the battery.




3. Master the basic knowledge of the lithium-ion UPS, carefully read the operation manual of the mechanical equipment, and understand the contents of various warning information, warning codes, meanings of display lights, causes, and preventive measures. Understand the functions of various power switches and buttons on machines and equipment. Understand the actual operating conditions of various ups and have a clear understanding of their connections and relationships.




4. Strengthen daily inspection and maintenance, check whether the equipment has alarm, odor and abnormal noise, check whether the joint is loose and hot, whether the cooling fan is running normally, whether the mechanical equipment is normal, and solve the problem immediately.




5. Maintain proper working temperature. Operating temperature is a key factor affecting the service life of lithium-ion battery ups. The optimum operating temperature specified by battery manufacturers is generally between 20 and 25℃. Once the operating temperature exceeds 25℃, the number of battery cycles will be every 10℃




6. Cut it in half. Replace the damaged rechargeable battery immediately. In the continuous operation and application of lithium-ion UPS power supply, it is difficult to avoid damage to some rechargeable batteries due to the differences in characteristics and quality. When one or more rechargeable batteries in a lithium battery pack are damaged, maintenance personnel should treat each rechargeable battery and conduct regular inspections and tests to remove the damaged rechargeable batteries.




7. The natural environment of switching power supply should have good natural ventilation, which is conducive to heat dissipation and keep the natural environment clean. Do not carry magnetic induction load, such as money counting machine, daylight lamp, central air conditioning, so as not to damage the UPS power supply.




8. Do not turn the ups off and on frequently. Typically, the UPS power supply can be turned on again after being turned off for 6 seconds. Otherwise, the UPS power supply may be in the Failed startup state. That is, the UPS power supply is not in the voltage output or inverter output state.




9. Maintain the UPS power supply. There is dust in the equipment. Measure the operating voltage of the lithium battery string correctly, check the running status of the cooling fan, and check and adjust major parameters of the UPS power system software.












Disclaimer:


1. Some articles and pictures come from the Internet;


2. Due to editing needs, there is no necessary connection between the text and the picture. It is only for readers' reference and does not represent the views of the platform, nor does it constitute investment advice or decision-making advice, nor does it provide material for any user transaction.


3. We have reproduced all the articles, pictures, audio video file information such as copyright belongs to the copyright shall belong to the original people, because of the original articles and pictures, etc can't contact and copyright, such as the author or editor that work should not be access to the Internet for everyone to browse, or should not be used free of charge, or involve copyright issues, please inform us in time, to take appropriate measures to quickly Avoid causing unnecessary economic losses or copyright disputes to both parties;